Catalog by type of application

Manifold Dräger RE
Manifold Dräger RE

Manifold Dräger RE

Manufacture: Dräger

Single-Sided Cylindrical Manifold (RE)

The RE1200 and RE500 pressure regulators are designed to reduce the outlet pressure of a cylinder battery to a medium pressure level, ensuring connection to a gas regulation station as a third source. They are used in central medical gas supply systems in hospitals, guaranteeing an uninterrupted gas supply. The manifolds are available in Control and Basic versions, allowing users to choose the optimal option based on their needs.

Key Advantages:

  • High level of safety and reliability.
  • Compliance with DIN EN ISO 7396-1 and EN ISO 15001 standards.
  • Fire-resistant BAM-certified design for oxygen use.
  • Possibility of connection to a gas regulation station.
  • Built-in filter for gas purification.
  • Available in two versions: Control and Basic.
  • Wide input pressure range (60 - 200 bar).
  • Optimized gas consumption and stable output pressure.
  • Easy installation and maintenance.

Differences Between Control and Basic Versions:

RE1200 Control / RE500 Control

  • Equipped with an electronic pressure sensor.
  • Can be connected to the GCS Control gas control station.
  • Additional Class 1.6 pressure gauge for backpressure indication.
  • Ensures continuous pressure monitoring and automatic alarm signals.

RE1200 Basic / RE500 Basic

  • Pressure control is performed via a contact pressure gauge.
  • Connects to the GCS Basic version or can be used independently.
  • Contact break at pressure drop below 17 bar ± 3 bar.
  • Cost-effective solution for backup gas supply.

Technical Specifications:

RE 1200

  • Nominal flow rate: 120 Nm³/h
  • Input pressure: 60 - 200 bar
  • Output pressure: 14 ± 0.5 bar
  • Weight: approx. 5.6 kg
  • Operating temperature: -20°C to +60°C

RE 500

  • Nominal flow rate: 35 Nm³/h
  • Input pressure: 60 - 200 bar
  • Output pressure: 14 ± 0.5 bar
  • Weight: approx. 4.2 kg
  • Operating temperature: -20°C to +60°C

Scope of Supply:

  • Cylinder bracket
  • Gas cylinder
  • Cylinder valve
  • Outlet pipeline of the manifold
  • Connection branch
  • Outlet valve
  • Manifold
  • Sintered filter for a single cylinder or sintered high-pressure valve
  • Filter for two or more cylinders
  • Pressure regulator
  • Installation and operation manual

Applications:

  • Hospitals and medical facilities
  • Laboratories and research centers
  • Industrial enterprises using gas systems
  • Emergency and backup gas supply sources
  • The single-sided cylindrical manifold (RE) ensures efficient and safe gas supply, meeting the highest quality and safety standards.