Catalog by type of application

Dräger Babylog® VN600/800 ventilators
Dräger Babylog® VN600/800 ventilators

Dräger Babylog® VN600/800 ventilators

Manufacture: Dräger

Dräger Babylog VN600/800: Expert Ventilation for the Most Vulnerable Patients

The Babylog VN600 and VN800 mechanical ventilators represent the pinnacle of neonatal respiratory support evolution from Dräger. Designed specifically for neonatal intensive care units, these systems provide lung and brain protective ventilation for patients weighing from 0.4 kg, ensuring safety at every stage of care.

Babylog® VN600/800

Intelligent Respiratory Support

The Babylog VN600/800 combines advanced invasive and non-invasive ventilation technologies with an intuitive interface. The devices allow seamless transitions between O2 therapy, CPAP, and high-frequency oscillation (HFO) without changing the breathing circuit, minimizing stress for the infant.

Key System Capabilities:

  • Volume Guarantee (VG) — Dräger's unique technology that automatically adjusts inspiratory pressure to achieve target volume. This prevents volutrauma and barotrauma, ensuring stable ventilation even when lung compliance changes.
  • High-Frequency Oscillation (HFO) with Volume Guarantee — combining the effectiveness of HFO with the safety of Volume Guarantee for the most critical patients.
  • Automatic Leak Compensation — intelligent algorithms instantly adapt triggering and flow, ensuring synchronization even with non-cuffed endotracheal tubes.
  • Smart Pulmonary View — real-time visualization of breathing mechanics, helping physicians instantly assess changes in resistance and compliance.

Babylog® VN600/800

Ventilation Modes for Any Clinical Situation

The devices support a full spectrum of modern modes, providing therapeutic flexibility:

Controlled Ventilation: PC-CMV, PC-SIMV, PC-AC, PC-PSV, PC-MMV (Mandatory Minute Ventilation).

Spontaneous Breathing Support: SPN-CPAP/PS, SPN-CPAP/VS, SPN-PPS (Proportional Pressure Support).

Special Modes: PC-HFO (High-Frequency Oscillation), APRV (Airway Pressure Release Ventilation), and Automatic Tube Compensation (ATC).

Ergonomics and Integration

The Babylog VN600/800 design focuses on staff comfort and patient safety. The glass touchscreen (15.5" in VN600 and 18.3" in VN800) is easy to disinfect, which is critical for preventing healthcare-associated infections.

  • Quiet Operation: the devices operate almost silently, creating a favorable environment for neonatal development.
  • Autonomy: built-in battery and optional external power supply PS500 ensure uninterrupted operation during transport.
  • Independence from Gas Supply: optional compressor module GS500 provides compressed air even without central gas distribution.

Babylog® VN600/800

"DM-PROJECT" offers a full range of services: from selecting the Babylog VN600/800 configuration to staff training and maintenance support.

Catalog by type of equipment